Trisula bridge piers located at the delta of Brantas River do not have any protection from the stream of the river when flooding. The purpose of the design is to find out the scouring happens to piers caused by the river flow, to determine what kind of protection used to protect the piers, to plan the implementation method, to find out the cost, and the implementation time.

Water discharge, pier dimensions, the span and depth of the river, the condition of piers, and velocity of the flow were needed to find out the scouring by Hydraulic Engineering Circular No. 18 application. The result was employed to determine the type of the protection. To find out the estimated costs were calculated through SNI-2012. Ms. Project were applied to find out the implementation time.

Keywords: bridge, piers, scouring, partially grouted riprap


Full Text:

PDF


DOI: http://dx.doi.org/10.33795/prokons.v8i2.71

Refbacks

  • There are currently no refbacks.


Copyright (c) 2017 PROKONS Jurnal Teknik Sipil



INDEXING : 

The following is an indexing list that includes the journal of the Prokons, published by the Civil Engineering Department, Politeknik Negeri Malang

          

   

     

 

_______________________________________________________________________________________________

Jurusan Teknik Sipil Politeknik Negeri Malang

Jalan Soekarno-Hatta No. 09, PO BOX 04 Malang 65141

Telp  0341-404424 ||  Fax  0341-404420

ISSN  Print (1978-1784) ||  Online (2714-8815)

Email  : prokons@polinema.ac.id

 

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License .